now in your cart 0 items
Tell A Friend
 
Tell someone you know about this product.

alpha-pH2000 Wall Mount/Panel Mount pH/ORP Analyzer

Our Price

£593.74

Product Features

  • Built-In Programmable for On/Off, Proportional, or PI (Proportional integral control) - suitable for most demanding precision process control applications
  • User-Customization through Advanced Setup Menu offers flexibility in matching the controller's functions to suit individual's specific needs
  • Automatic Calibration with Auto-Buffer Recognition removes mistakes during calibration
  • Symmetrical Mode Operation stops electronic noise problems when used with solution ground
  • Backlit Display provides for reading in low-light conditions
  • Universal Power Supply Input from 85 to 250 VAC/DC allows use at multiple locations and withstands voltage fluctuations
  • Rugged NEMA 4X housing helps to protect the controller from the elements and dirty industrial applications
  • 2 Level Password Protection prevents unauthorized tampering with settings
  • 0 to 2000 Second Time Delay Adjustment on control and alarm delays
  • Hold Relay for use with float switches/flow switches and other controllers as a failsafe function
  • 2 Galvanically Isolated Scaleable 0-20/4-20 mA Outputs for pH/ORP and temperature
  • Wash Contact Relay controls electrodes cleaning systems at desired time period and frequency
  • Choice of Glass or Antimony Electrode for general use or hydrofluoric acid applications
  • Adjustable Hysteresis (Dead Band) helps prevent rapid contact switching near set point
  • Non-Volatile Memory retains all stored parameters and calibration data even if the power fails 
  • Large Dual Display shows pH (or ORP) with temperature simultaneously - features multiple icons, set points, and status messages
  • Choice of Temperature Sensor Pt100/Pt1000 with 2-wire or 3-wire temperature input selection
  • Simple Installation and Wiring with detachable plug-in connectors
  • Panel-mounted version is also available

Applications

General:
Very useful for any batch or on-line type application that requires accurate pH or ORP control.

Water Treatment:
Use for batch and on-line control of incoming process water, rinse water treatment, recirculating system and waste water treatment.

Industrial: 
Suitable for chemical processing, food processing. aquarium, pharmaceutical, hydroponics and waste control industries.

Regulatory:
Hook to recorder to document data for regulatory compliance.


Specifications

pH Range-2.00 to 16.00 pH
Resolution & Accuracy0.01 pH & ±0.01 pH
mV Range-1000 to 1000 mV / 0 to 100% (for -100 to 100 mV)
Resolution & Accuracy1 mV / 0.1% & ±1 mV / ±0.2%
Temperature Range-10.0 to 110 °C (14.0 to 230.0 °F)
Resolution & Relative Accuracy0.1 °C / °F &
±0.5 °C / ±1.0 °F
Temperature SensorPt100/ Pt1000 (jumper selectable); 2 or 3 wire
Temperature CompensationAuto / Manual
(Reference at 25°C)
Set Point and Controller Functions
Integral Time 0 to 999.9 minutes
Switching pH Hysteresis0.1 to 1 pH
Function (Switchable)P/PI control (Pulse Length / Pulse Frequency);
Limit Control; Off
Adjustable Period with Pulse Length Controller0.5 to 20 seconds
Adjustable Period with Pulse Frequency Controller
60 to 120 pulses/min
Pickup / Dropout Delay0 to 2000 seconds
Wash Cycle0.1 to 200.0 hours
Wash Duration 1 to 2000 seconds
Contact Outputs, Controller
1 SPDT, 3 SPST relays
Switching Voltage / Current / PowerMax 250 VAC / Max 3A / Max 600VA
Alarm Functions
Function (Switchable)
Latching / pulse
Pickup Delay0 to 2000 seconds
Display
LCD
UV coat, backlit 14 segments display with symbols for status information
BacklightOn/Off selectable with four levels of brightness control
Electromagnetic Compliance (EMC) Specifications
Emitted Interference
According to EN 61326
Immunity to Interference According to EN 61326
Environmental Conditions
Ambient Temperature Operating Range 0 to 40 °C
Maximum Relative Humidity 80% up to 31 °C decreasing linearly to 50%
at 40 °C
Power Supply
Input
80 to 250 VAC/DC 50/60 Hz Approx. 10 VA
Main Fuse
250 mA, Anti-surge, S504 BUSSMAN
Pollution Degree 2
Transient Overvoltage Category II
Electrical Data and Connections
Transmitter FunctionTwo 0/4 to 20 mA scalable outputs for pH/ORP and temperature, galvanically isolated
CU 22 Function22 mA current output
Isolated Output Voltage +12V ±0.5 V (Max 50 mA)
Hold Function Switch
To freeze output current and deactivate control relays
LoadMax 600 W
pH InputBNC (1012 impedance); Asymmetrical/ Symmetrical
Connection Terminal
(Wall Mount)
3-pin, 8-pin, 9-pin and 13-pin terminal, detachable blocks
Connection Terminal
(Panel Mount)
3-pin, 9-pin and 19-pin terminal, detachable blocks
Mechanical Specifications
Dimensions (W x H x D)Wall-mount
Panel-mount
144 x 144 x 110 mm
96 X 96 X 175 mm
WeightWall-mount
Panel-mount
745g (Unit) / 1100g (Packed)
950g (Unit) / 1100g (Packed)
Environmental RatingWall-mount
Panel-mount
IP66 (NEMA 4X)
IP54 (front panel)



  • Model: Alpha pH2000

Add to Cart




Add to Cart:


This product was added to our catalog on Monday 22 June, 2009.